Wednesday, May 29, 2019

[MW:29651] ERNiCU7 TIG hot wire cladding weldabilty

Gents , 
Currently am developing procedure using hot wire TIG process using ERNICU7 CLADDING , 
Thickness of cladding minimum 3.2mm , 2layer only
Fe value to be less than 2.5 after 2 layer .
Can you please share your experience regarding the weldability issue and precaution to take care during weld procedure?
Regards 
Neilashkumar 

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material