Thursday, October 3, 2013

Re: [MW:18838] PQR for Gr. P91

only one pipe 6"sch 160 is enough for that PQR . to cover the max. thk. and imact test if required.
 

Thanks
Mohamed El Sayed
Senior QC Welding Engineer
 

From: sumod s <sumod.sadhupuram@gmail.com>
To: materials-welding <materials-welding@googlegroups.com>
Sent: Thursday, October 3, 2013 6:53 AM
Subject: [MW:18836] PQR for Gr. P91

Dear Experts,
 
I need to do a  PQR for SA335 Gr.P91. The maximum thickness requirement for site welding is 30.96 mm. I am planning to use 6" sch 160(18.24 mm) pipe as it is available with us. But I need to confirm whether welding of one such piece is enough or not as we have to do 2 tension & 4 side bend tests. Please confirm the other requirements also.
 
Sumod
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.


No comments:

[MW:34920] Tubesheet Hole step

Hello Team, I have one question any tolerance given for tubesheet Hole step. Please do needful. Regards, AP  -- https://materials-...