In my opinion this is a poor start / stop which they tried to repair with the short weld. The visible defect is a still lack of side wall fusion and because of this you also face incomplete fill of the joint at this location.
Because of the presence of (deep) lack of fusion it should become rejected by any code.
Met vriendelijke groeten / Best Regards,
Herman Pieper
QA-QC Inspector / IWI-C / IWT / Materials expert
Job van der Havestraat 6
8384 DB, Wilhelminaoord
Tel: 06-51691215
Van: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] Namens Sathish Kumar
Verzonden: maandag 19 november 2012 10:41
Aan: materials-welding@googlegroups.com
Onderwerp: [MW:15959] What kind of weld defect? pl advice..
Dear experts,
pl find attach.
it is a structure welding. fillet weld.
What kind of defect is this? whether this is acceptable or reject as per spec/code. pl specify exact reference.