Dear Sir,

 

Please find the Extracts of Clause T276.2 (a) of Article 2 of ASME Sec. V Ed. 2010.

 

The thickness on which the IQI is based is the nominal single-wall thickness plus the estimated weld reinforcement not to exceed the maximum permitted by the referencing Code Section. Backing rings or strips shall not be considered as part of the thickness

in IQI selection. The actual measurement of the weld reinforcement is not required.

 

Basis on the above, you will have to select either Hole type IQI Designation 12 or 1A wire identity No. 5 or both you can place on the weld for judging better sensitivity.

 

Thanks & regards,

 

 

C. R. GANDHI

(Manager- Q.A./ Q.C.)

--- On Fri, 6/1/12, pradip kumar sil <pradipsil@gmail.com> wrote:


From: pradip kumar sil <pradipsil@gmail.com>
Subject: [MW:14445] Re: IQI Selection in DWSI Technique
To: materials-welding@googlegroups.com
Date: Friday, June 1, 2012, 11:58 PM

Dear Experts,
As per Sec V which IQI ( 1A /1B ) to be used and which  wire to be
visible for 1" & 2.9 mm thickness DWSI technique.
Regards
Pradip

On 5/31/12, pradip kumar sil <pradipsil@gmail.com> wrote:
> Dear experts,
>
> Can any one answer the following: one inches butt weld is radiograped
> double wall single image technique. The wall thickness is 2.91 mm and
> weld reinforcemnt is 1.6mm. In accordance with ASME-V article-2 T-276
> what will be the thickness that the penetrameter based on. In another
> way the thickness that the penetrameter based on will be
> (2.91mm+1.6mm=4.51mm) or (2.91 mm+2.91mm+1.6mm +1.6 mm=9.02mm) ?
>
> The "interpretation" of ASME Section V clearly defines the "Material
> thickness" in question.
> The height of weld reinforcement at both sides of pipe is applicable
> in this case &
> which wire is be visible
> Looking forward to have your answer with appreciation.
> Many Thanks in advance
>
> Regards
> Pradip
>

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...