Skip to main content

Re: [MW:10884] RE: 10879] Duplex Claded Eqipt PWHT

Dear Mr Herman Pieper
Thanks for Suggestion
My openion ,which can be debated
i) If I carry out restoration of cladding by barrier layer of ry 309LMo chemistry  and carry out PWHT as per code
ii)After PWHT go for rest of the layer by Duplex electrode and no further PWHT
(Of course PQR is to be qualified accordingly)
What is your openion ?
Regards
Hegde P.B.


From: Pieper QSI <pieper-qsi@kpnmail.nl>
To: materials-welding@googlegroups.com
Sent: Fri, 29 April, 2011 12:51:54 PM
Subject: [MW:10883] RE: 10879] Duplex Claded Eqipt PWHT

Dear Mr. Hedge,

 

When executing PWHT at 600 °C your corrosion resistance will be reduced because of the formation of Sigma phase (FeCr precipitates) in the microstructure of the cladding. Sigma phase can occur in the temperature range from 450 °C – 850 °C so if you will discuss lowering the PWHT temperature you should go for 400 max. but I would choose to propose withholding PWHT and take care of controlling welding parameters during production.

You may propose executing portable MicroVickers hardness tests after weld completion in order to demonstrate no high hardness values are present at the HAZ near weld surface.

Most important is to convince your client to withhold PWHT because of the corrosion resistance of the cladding. When client insist on any kind of stress relieve treatment you perhaps can convince them to use high frequency hammering of the cap layer and HAZ. This will introduce compressive stresses in the surface up to 2 mm instead of the tensile stresses present after welding.

 

Met vriendelijke groeten / Best Regards

 

Herman Pieper

 

Pieper Quality Support & Inspection

Phone: +31 (0)521 380083

Fax:     +31 (0)84 7539225

Cell:     +31 (0)6 51691215

www.pieper-qsi.nl

 

Van: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] Namens Prakash Hegde
Verzonden: vrijdag 29 april 2011 6:31
Aan: materials-welding@googlegroups.com
Onderwerp: [MW:10879] Duplex Claded Eqipt PWHT

 

Dear Friends

I have a query about The Duplex  cladded E quipment having base material SA 516 Gr70 of 50mm thk and clad of Duplex (3mm )

The eqipment require to undergo PWHT at 600C The Joint is clad restored by Duplex weld

 

i) Does the PWHT at 600C will affect  the Corrosion properties of Duplex weld (Corrosion test like IGC,Pitting corrosin,etc  as per GS8)

ii) If yes do we require to carry out PWHt at lower Temp.

 

Regards

Hegde P.B.

08805593046

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

[MW:30043] Weep hole

If weep hole is not provided in dummy pipe before welding What will happen??? -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/da251ee6-fa7f-4851-b876-cdb3834ae341%40googlegroups.com .

[MW:36169] Cold Bending Qualification

Dear Experts,  Can anyone share the inspection requirements or a qualification procedure for cold bending? Our client spec states only the requirements for induction bending and would like to know your opinion on the cold bend inspection requirements. The code of construction is B31.3, Max. 5D bends, A106 SS 316L.  Thanks in Advance. -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/materials-welding/1be61cc3-e9c9-4a5f-834d-e8485e248432n%40googlegroups.com .