Wednesday, March 23, 2011

[MW:10455] A No.

Does Weld Metal Chemical analysis (A No.) is an essential to be mentioned while qualifying PQR for meeting ASME B 31.3?
 
Please let me know the clause if possible mentioning the above details.
 
 
Regards,
Jaydeep

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...