Regading the PQR/WPQ,if the welder Qualified in 1G position in 8 mm thck plate full penetration welding,what will be the qualified range in pipe .
 
regards,
kvr

No comments:

Re: [MW:35501] TEST COUPON ASME SEC IX

Yes, You can machine the Plate.  Prepare the Welding Running Sheet and mention 14 mm Plate machined to 8 mm Plate.  then the groove weld qua...