Heat Input is goint to be the key factor in this case, which would be less for GTAW.
so for GTAW, there would be more UTS.
Due to limited information, this is only thing i can predict, else more info like heat treated condition and weld joint, would be needed.
Regards
Manpreet Singh
Welding Engineer
On Fri, 17 Dec 2010 8:43:49 , Harish Kannepalli <harishkannepalli@gmail.com> wrote
In theory both will have same UTS. But while testing, slight variation may be there due testing conditions.
--
-- 2010/12/16 Shaunak Upadhyay <shanupadhyay@gmail.com>
1) Material Specifcaiton: SA 516 GR 70
Size: 6.0 mm thk
300 mm Length x 300 mm Width
Process: GTAW
Consumable: ER70S-2
2) Material Specifcaiton: SA 516 GR 70
Size: 6.0 mm thk
300 mm Length x 300 mm Width
Process: SMAW
Consumable: E7018
Which test piece have more UTS in these two processes.
Regards,
Shaunak Upadhyay
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
regards,
Harish.
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments:
Post a Comment