Dear All,

we are using  FILLER WIRE ER 90SB3 FOR SA387GR22 CL-2 thk 6mm...we are are pre-heating to 150 with  torch....after doing tacking, about 95% of tacks are found to have cracks .We have not released for Welding.The filler material is checked and ok. pls give your sugestions.

Regards

Vasu

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...