dear
it's accepted .but NCR should be done acc.to your quality manual &put NCR NO. beside this activity in ITP
regards
H.KASHKOUSHA From: manohar matcha <matchamano@rediffmail.com>
To: materialswelding <materials-welding@googlegroups.com>
Sent: Mon, November 1, 2010 7:53:37 AM
Subject: [MW:7980] R/F Pad plate thickness
Dear All,
Situation:
Dished head nominal thk.8mm / Minimum thk.6mm
Shell thk.6mm
Code of construction: ASME Sec.VIII Div.I
Is it acceptable to use 10mm thk R/F pad plate (due to non availability of lesser thk plate) for a nozzle suppose to be welded on above mentioned dished head...?
Regards,
Manohar.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.