Dear Manohar,
No problem, it does not violate the Code. Customer should agree.
But other case, some customer requests R/F pad shall not be under than shell/head thickness.
Thank you.
On Mon, Nov 1, 2010 at 12:53 PM, manohar matcha <matchamano@rediffmail.com> wrote:
Dear All,
Situation:
Dished head nominal thk.8mm / Minimum thk.6mm
Shell thk.6mm
Code of construction: ASME Sec.VIII Div.I
Is it acceptable to use 10mm thk R/F pad plate (due to non availability of lesser thk plate) for a nozzle suppose to be welded on above mentioned dished head...?
Regards,
Manohar.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
Regards,
T. Rizal Hidayat
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.