Thursday, September 17, 2009

[MW:3245] Re: Shelf life of Low hydrogen electrodes

gents,
 
the validity of low H2 electrodes for 2.5 & 3.2 mm. is 3 years from mfg date. it is normally visually inspected for any damaged electrodes.
 
chandrakant mohikar
 

 
On 9/17/09, Ravindra T <indra.tiru@gmail.com> wrote:
Dear All
 
Our contractor has brought low hydrogen electrodes (E 7018 & 8018) which are manufactured in 2007 for welding station piping in one of our intermediate pump station of our cross country pipeline project. I would like to know whether these electrodes can be used now?. Is there any reference in ASME code regarding the expiry/ shelf life of Electrodes?
 
Please advise me in this regard.
 
Thanking you all in advance
 
Ravindra
Senior Project Engineer
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

[MW:34920] Tubesheet Hole step

Hello Team, I have one question any tolerance given for tubesheet Hole step. Please do needful. Regards, AP  -- https://materials-...