[MW:3103] Re: Hydrotest for high pressure piping

Tong,
 
you should perform a pressure test on the pipeline, do you have valves in the line? there must be some tie-in points or valves in the line?
 
Nick Davies

On Wed, Sep 2, 2009 at 6:19 AM, tong tong <tong2je@gmail.com> wrote:
Dear All,
I have one tie-in point. The material is SA 312 TP316L. The test pressure is 350 bar and operating pressure is 250 bar. The big problem is there are no isolation point so hydrotest can't be performed on it. When I refer to API 570, clause 8.2.6 stated that when a pressure test is not necessary or practical, NDE shall be utilized in lieu of a pressure test. Due to this line is high pressure, is it enough only perform the NDT ? How suppose i do to convince our management level regarding integrity of the weldment ? Please help me. Thank in advance and you cooperation is highly appreciated 
Regards
Tong2je






--
Regards,

Nick Davies

--~--~---------~--~----~------------~-------~--~----~