Dear All,
We have a job ( hydro generator) material SA 387 Gr.11 CL 2 + SS347 ( clad) ,required impact testing at (minus)-18 Deg.C with energy value 33 J average (irrespective of MDMT ),having some nozzles (LWNR) material is SA 182 F 347.
For Welding Procedure Qualification of Dissimilar metals Nozzle to Shell joint ( P4 To P8) using electrodes by E309L , weld Impact test is required or not?
As per ASME SEC VIII Div 1 – UHA-51 (e) it is exempted ,
Please advise.
Thanks in advance.
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/