As per B31.8 considering worst situation of Zone 3 & 4 the min pressure at which Hydro is to be done is 1.4XMOP(max operating pressure) and max at which the hydro can be done is either at a design pressure or at a pressure more than the design pressure.For example if DP is 92 and MOP is 45 then min hydro pressure is 1.4X45=63 but if you carry out Hydro at 150 then your max ALLOWABLE operating pressure becomes 150/1.4=107 but since it is more than DP i.e.92 MAWP shall be only 92 and not 107.
Regards
Aarpee
On Mon, Jul 20, 2009 at 12:34 PM, peyman khazraei
<pkhazraei@gmail.com> wrote:
Dear all
can any body help me for:
as construction code for gas compressor station ASME B31.8 ,whats the pressure of hydrostatic test of piping with equipment like air gas cooler as system .
by to ASME Bb31.3 the pressure test must be according to the vessel or equipment design but i can't ind answer of my question in B31.8 (gas transmission piping......)
thnks
peyman
¡Obtén la mejor experiencia en la web!
Descarga gratis el nuevo Internet Explorer 8.br> http://downloads.yahoo.com/ieak8/?l=mx --~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---
Any advice for cast iron welding Sent from Yahoo Mail for iPhone
No comments:
Post a Comment