Impact testing temperature shall be your MDMT, not the working temp. check with your designer for MDMT.
BTW pl. don't repeat queries?
On Sat, Jul 25, 2009 at 10:52 AM, Nikhil <nikhilrp_2006@rediffmail.com> wrote:
Dear Friends,
I like to know whether we can use the combination of E6010 in root and E7018-1 as filler in LTCS (A333Gr6) welding, particularly in Ammonia service (flash point is minus 33 deg C)?
The working temp is less than minus 33 deg C. At what temp should I impact test it?
Regards,
Nikhil
QC Engineer
Sharjah, UAE
+97150 1453525
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---