This type of leaking also happened at one of my project. As far as I know, reason behind this leak is due Chloride Stress Corrosion Cracking. This type of cracking and leak occurs when water with high chloride content is used for hydrotesting of 300 series SS, and not drained properly after testing. You may refer API 571 section 4.5.1 Chloride Stress Corrosion Cracking (Cl-SCC) for more information.
Regards,
Ahmed Husain
Mob-0547170325
Mob-0547170325
From: k.ilangkumaran ilangkumaran <k.ilangkumaran@yahoo.com>
To: materials-welding@googlegroups.com
Sent: Mon, June 20, 2011 8:46:11 AM
Subject: [MW:11396] SS 304L piping leaking
Dear experts, Could you please anyone explain me why SS 304L piping leaking. Its service is just utility water and duration of service is not even 1 year. Also leaks were observed many locations only on weld and HAZ. What could be the causes leak? Regards Ilangkumaran |