Hi,
make the procedure with inconel and avoid PWHT.
Thanks & Regards
Muhammed Ibrahim PK
On 5 February 2011 17:38, shaji prabhakaran <shajivaliyakulam@gmail.com> wrote:
Friends,
I have few joints of Inernally FBE coated pipes CS pipes of thk>20mm.
The joint design is a single V, with internal sleeve to protect the
corrosion in the weld joint area(paint burned out area in the HAZ).The
sleeve is of a special design to withstand the welding heat and the
ends are having epoxy mastic and a pair of 'O' rings at both end to
avaoid ingress of corrosive fluid to the weld area.
In general thickness of pipe is <20mm and heat treatment is not
required. But there are few cases of higher thickness for which heat
treatment is required as per code.But heat treatment will damage the
coating inside and not possible.The welding process is SMAW down hill
which uses electrode E6010+7010.
Any alternative or practical suggestions to avoid heat treatment in
this case??
Shaji Prabhakaran
Welding Engineer.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.