Skip to main content

RE: RE: [MW:3802] type coated Bolts carbon steel bolts ( A193 Gr. B7 ) fo Stainless steel flanges

Duplex SS bolts are costly. But on the other hand, at least in our region we do not wish to compromise the safety.
 
Insulation gaskets/kits need to be fire-safe if used in hydrocarbon service.
 
Unfortunately, now where asbestos is prohibited in most contries, standard insulation kits are with washers and sleeves made in PTFE (teflon).
They are not fire safe, during a fire they will become soft and eventually melt - and the flanged connection will open. This may release hydrocarbons to the fire.
 
Regards
Kristian


From: Chandra Bhusan Tripathi [mailto:cbt@rediffmail.com]
Sent: 7. december 2009 13:16
To: ranasr@npcc.ae
Cc: materials-welding@googlegroups.com
Subject: Re: RE: [MW:3800] type coated Bolts carbon steel bolts ( A193 Gr. B7 ) fo Stainless steel flanges

Hi Everyone,

SS bolts are very costly and not all coustomer advise to use in all lines, It depend how critical is your line is otherwise, galvanise bolts with insulation washer (kit) is a cheaper option instead of  SS bolts.

Regards

Chandra Bhusan Tripathi

On Sun, 06 Dec 2009 15:25:03 +0530 wrote
>

Please inform bolts are required for onshore or offshore environment.

In offshore environments,

For SS flanges, even SS304 /316 ( due to crevice corrosion problems in corrosive atmosphere ) Bolts are not preferred,

CS Galvanised bolts are any way not preferred due to galvanic corrosion problems ( I think )

We use

a. UNS 32760 Bolts or

b. CS/LTCS + Fluropolymer coated bolts (see attachment)

Regards,

Shivanand R Ranasaria


From: desaid@toyoindia.com [mailto:desaid@toyoindia.com]
>Sent: Friday, December 04, 2009 3:18 PM
>To: materials-welding@googlegroups.com
>Cc: materials-welding@googlegroups.com
>Subject: Re: [MW:3795] type coated Bolts carbon steel bolts ( A193 Gr. B7 ) fo Stainless steel flanges


>

>Many Licensor's specification specifies A193 B7 / 2H bolts for stainless steel flamges.
>Use of galvanised bolt not seen at all for SS flanges.
>
>Also note, A193 B7/2H bolts are not CS bolts. These are alloy steel bolts.
>
>I did not understand the stage of your project . If youare planning to buy new one than buy ss bolts or can go for B16 / 4 bolts also.
>
>
>Thanks & Regards,
>Dhwani Desai.
>TOYO - PLANNING & PIPING DEPT.
>91-22-2573 7681.

>
>

"Pisat, R. R(ahul)"

12/04/2009 02:33 PM

Please respond to
>materials-welding@googlegroups.com

To

cc

Subject

[MW:3787] type coated Bolts carbon steel bolts ( A193 Gr. B7 ) fo Stainless steel flanges


>
>
>
Hello all,

Please recommend me the type of coated carbon steel bolts ( A193 Gr. B7 ) to use with stainless steel flanges.
>I am sure no to apply galvanised bolts with SS flanges.

Our construction team is worried about the rusted of the carbon steel bolts to be apply with stainless steel flanges.

Please reply your recommendation for type of coating for bolts ?

Kind regards

Rahul

--
>To post to this group, send email to materials-welding@googlegroups.com
>To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
>For more options, visit this group's bolg at http://materials-welding.blogspot.com/
>The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
>To post to this group, send email to materials-welding@googlegroups.com
>To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
>For more options, visit this group's bolg at http://materials-welding.blogspot.com/
>The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.


>
===================
>Please consider the environment before printing this email
>===================
>
>The information contained in this communication is intended solely for the use of the individual or entity to whom it is addressed and others authorized to receive it. It may contain confidential or legally privileged information. If you are not the intended recipient you are hereby notified that any disclosure, copying, distribution or taking any action in reliance on the contents of this information is strictly prohibited and may be unlawful. If you have received this communication in error, please notify us immediately by responding to this email and then delete it from your system. NPCC is neither liable for the proper and complete transmission of the information contained in this communication nor for any delay in its receipt.
>

--
>To post to this group, send email to materials-welding@googlegroups.com
>To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
>For more options, visit this group's bolg at http://materials-welding.blogspot.com/
>The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
>

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...