Monday, October 12, 2009

[MW:3495] Re: Welding of Sa-335 to SA-106

Hi,
 
You cannot use that PQR. Change in P number is essential variable.
 
Regards,
Ibrahim

2009/10/12 Jimmy Nielsen <nielsen.jimmy@gmail.com>

Hello Gents

Can sombody help me with a answar regarding welding of Sa-335 to
SA-106.

I have a PQR covering material 335-P11 to 335-P11( P4)
Can I use it for welding of P-no 4 to P-no 1

Regard, jimmy





--
Thanks & Regards
Muhammed Ibrahim PK

--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:34913] Filler wire