Dear Folks,
 

Some notes on 17-4 PH steel are as follows:-

 

Under ideal conditions, the alloy can be best welded when fresh from the mill, and supplied in solution annealed condition. After welding with matching SMAW electrode SFA 5.4 Type 630 or matching GTAW filler metal, one would get the best properties but the weld has to be  aged to get the ASTM/ASME code specified meachanical properties.

 

Generally 17-4 PH steel (UNS 17400) is covered in ASME-Sec-II Part-A , under specification, SA564 Type 630  and by ASTM specification A693 Type 630

 

If the alloy is supplied in solution annealed and aged condition, then welding it in situ with matching 630 electrodes would not be ideal, since the alloy already would have very high strength and very low ductility (typicall 8-14% depending on aging temperature).

 

The only and the best option is to weld with Austenitic S.S electrodes, such as E-ER 308/308L or E-ER-309/309L or Nickel based electrodes such Inconel 82. Use of austenitic electrodes would produce welds of under matching strength, such as:-

  • 17-4-PH –Base metal UTS  after solution anneal and aging, ³ 140Ksi
  • 308/309L electrodes, undiluted all weld  metal UTS  ³75  Ksi
  • Inconel 82 (E-NiCrFe3) electrodes, undiluted all weld  metal UTS  ³  80 Ksi

 

 Welding recommendations, e.g. technique, control of heat input etc  are same as  for 300 series of  austenitic stainless steels.
 

 

Thanks

 

Pradip Goswami

 

Welding Engineer/Specialist

Ontario Power Generation Inc.

Ontario.

 

> Date: Tue, 27 Oct 2009 23:17:45 +0700
> Subject: [MW:3554] Re: Electrode for 17-4 PH cast steel
> From: maringan.hutagalung@gmail.com
> To: materials-welding@googlegroups.com; novatekcorp@yahoo.co.in
>
>
> Dear all,
>
> Thanks for the replies.
>
> I am trying to recommend them to use Avesta 248 SV rutile electrode
> www.avestawelding.com/3206.epibrw
> Which I have it on our stock.
> I see that the chemicals composition and mechanical properties is only
> have a little bit different, while this type of electrode not comply
> to AWS E630
>
> @ Prem : I interest to your WPS when you apply E308L for your case,
> please send me directly a copy of it.
>
> Thanks for cooperation.
>
>
>
> Best regards,
> Maringan
>
> On 10/27/09, PREM SHANKARDUTT NAUTIYAL <prem_nautiyal@rediffmail.com> wrote:
> >
> > Hi
> >
> > We weld 17-4PH with E308L electrodes for SMAW process.
> > I will send you the complete welding procedure tomorrow if you require..
> >
> > Regards
> >
> > Prem Nautiyal
> > Cell:9820313278
> >
> > On Tue, 27 Oct 2009 18:01:48 +0530 wrote
> >>Sir
> > If 17-4PH is it pre trated to any specfic condition as like 950, 1075 or
> > 1100, 1150 ?
> > If pre trated , then it would be best to use 312 type electrode
> > Regards
> > Suneel Gore
> >>
> >>--- On Tue, 27/10/09, Maringan Hutagalung wrote:
> >>
> >
> >>From: Maringan Hutagalung
> >>Subject: [MW:3549] Electrode for 17-4 PH cast steel
> >>To: materials-welding@googlegroups.com
> >>Date: Tuesday, 27 October, 2009, 12:32 PM
> >>
> >>
> >
> >>Dear all,
> >>
> >>Our customer as a pulp and paper mill service are repairing
> >>a liner in a rotor housing, the material is a cast steel type 17-4PH.
> >>
> >>For repair of some defect caused corrosion and abrasion wear, they
> >>require an electrode AWS E630.
> >>
> >>Does anyone can give an advice for other type of electrode to
> >>substitute a E630 since
> >>we don't have stock of it.
> >>
> >>Thanks in advance
> >>
> >>
> >>Maringan
> >>
> >>--
> >>Sent from my mobile device
> >>
> >> From cricket scores to your friends. Try the Yahoo! India Homepage!
> >
> > PREM S NAUTIYAL
> > CELL : 9820313278
> > >
> >
>
> --
> Sent from my mobile device
>
> --~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...