Dear Prasanth,
Eaht you have done is correct and in general most of the clients are asking for the same extent of testing.
Try to take out the extent of inspection from the P.O given to vendor or ask the vendor take a letter a letter from the purchser.
Infuture try to avoid such inspection with out approved QAP.
Regards
N.Nageswararao
On Thu, May 28, 2009 at 1:11 PM, prashant pansare <prashantpan_99@yahoo.co.in> wrote:
Dear all,I' ve inspected ball & NRV ( API 6D) valves for xyz company.QAP was not available & client also not provided extent of check,but i inspected Hydro test 100% for body & 10% foe seat & released all the valves after satisfactory results.My firm wants clarification for Why i not done 100% testing for seat also?I' ve been warned,badly as i' ve carried out inspection without QAP & taken my own decision.Is there any specs. or std. to rsolve this matter? & if available pl.forward me,so that i canresponce immediately to avoid further action.Pl. help.Regards to all ...PRASHANT
Explore and discover exciting holidays and getaways with Yahoo! India Travel Click here!
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---