Skip to main content

[MW:2232] Re: 2225] min and max accepted resiual magnetisum

Rajeev,
Anything in excess of 6 gauss residual magnetism is known to cause problems in welding
such as arc blow.
Rgds,
Shashank Vagal


--- On Sat, 23/5/09, Pablo Acelajado <pjacelajado@npc.com.sa> wrote:

From: Pablo Acelajado <pjacelajado@npc.com.sa>
Subject: [MW:2230] RE: 2225] min and max accepted resiual magnetisum
To: materials-welding@googlegroups.com
Date: Saturday, 23 May, 2009, 2:07 PM

May 23, 2009

 

Dear Rajeev Arora,

 

You must be referring to manganese not magnesium since there is no range or max. for magnesium in API 5L Gr. 70.

 

For Manganese, the range depends on what type of pipe and what WT is involved or whether Seamless, Welded, PSL 1, or PSL 2. For safety you may have a limit of up to 1.4% max for seamless pipe unless otherwise agreed or it could go up to 1.8% for other types. You need to say the type and WT.

 

PJA

 

SAVE TREES  - THINK BEFORE YOU PRINT


From: materials-welding@googlegroups.com [mailto: materials-welding@googlegroups.com ] On Behalf Of rajeev arora
Sent: Friday, May 22, 2009 11:33 AM
To: materials-welding@googlegroups.com
Subject: [MW:2225] min and max accepted resiual magnetisum

 

Dear All,

 

Please give some reference of the max. or range of acceptance of megnetisum in line pipe of API 5L Gr 70.

 

Reagrds

 

Rajeev Arora


--
Regards

Rajeev Arora




"DON'T LET SOMEONE BECOME A PRIORITY IN YOUR LIFE...
WHEN YOU ARE JUST AN OPTION FOR THEM....."

SO , Always keep in mind that......

DON'T GO THE WAY LIFE TAKES YOU,
TAKE THE LIFE THE WAY YOU GO,





Explore and discover exciting holidays and getaways with Yahoo! India Travel Click here! --~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...