[MW:2201] RE: 2187] RE: 2184] Ovality tolerance

For this Inner dimension (4300mm), if we  target %0,25. Is that mean about +-102mm ?

Regards,

 


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of PB HEGDE
Sent: Wednesday, May 13, 2009 2:10 PM
To: materials-welding@googlegroups.com
Subject: [MW:2187] RE: 2184] Ovality tolerance

 

Dear Anil

 

Please refer UG80 of Sec VIII Div 1 You can have 1% ovality is acceptable but It is case to case basis i.e Higher the Dia , it should be kept less than 0.5% even the acceptable tolerance is high b) higher ovality will cause more offset in weld seam

ii) In case of heat exchanger , You can not afford to accept higher ovality . You should target less than 0.25% ,Higher ovality will give problem in tube bundle insertion.

Regards

 

Hegde P.B.

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of N Anilkumar
Sent: Wednesday, May 13, 2009 4:04 PM
To: materials-welding@googlegroups.com
Subject: [MW:2184] Ovality tolerance

 

Dear All,

 

Can anybody tell me,

what's the ovality tolerance of cylindrical shell pressure vessel (ID 4300 mm and plate thickness 12mm).

 

Regards,

Anil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 




__________ Information from ESET NOD32 Antivirus, version of virus signature database 4070 (20090513) __________

The message was checked by ESET NOD32 Antivirus.

http://www.eset.com


__________ Information from ESET NOD32 Antivirus, version of virus signature database 4081 (20090517) __________

The message was checked by ESET NOD32 Antivirus.

http://www.eset.com


--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

1 comment:

Anonymous said...

Keep posting stuff like this i really like it

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...