Yes if the other essential performance qualification parameters (process, F no, P No etc) are not altered

Dr. G. Dilintas - Authorized Inspector Supervisor
I&F Regional Technical Manager
Bureau Veritas Piraeus - Greece
Tel: +30 210 40 63 113/4
Fax: +30 210 40 63 118
Cell: +30 69 44 64 62 04

Inactive hide details for Ahmed Husain <ahmraha@yahoo.com>Ahmed Husain <ahmraha@yahoo.com>

Ahmed Husain <ahmraha@yahoo.com>
Sent by: materials-welding@googlegroups.com

07/11/2010 12:38

Please respond to
materials-welding@googlegroups.com

To

materials-welding@googlegroups.com

cc

Subject

[MW:8122] weld thicness

Ref

 


Dear All,
I need your valuable information/comment on following case.
There is a situation where 2 welders are qualified to weld 12mm thick. Ifthe job thickness is 20 mm and dia, say is 36”, contractor divide the joint in half. First simultaneously, each will weld approx 10mm thick including root half the circum, as they are qualified in 12 mm only. Then the interchange their location and they will complete the remaining welding. Basically these 2 welders who are qualified upto 12 mm are welding 20mm thickness joint, but at any given location they are welding 10mm thickness.

Is this practice is acceptable.

Regards,

Ahmed H.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.