Is it plate . I assume it is ASTM-A-240 . You R right . Minimum requirement is 10 % . But what is the error or accuracy of PMI equipment . In my view , it can be accepted
On Thu, 28 Mar 2019 at 15:44, Sameer <sameer.landgebv@gmail.com> wrote:
Dear Experts ,--During PMI testing of SS316 material Ni observed - 9.86% , required range is 10-14%.observed value will be accepted or not . Please provide your valuable comments .