To my knowledge ,its a fault in weld design .
On Thu, Apr 4, 2019, 16:23 Arun Padman <arunpadman0105@gmail.com> wrote:
--Dear All,
I have a situation in which I need to qualify a WPS with 40mm root gap and 10mm base metal,
But the client is not ready to allow us to conduct the PQR, he need a technical clarification before we conduct PQR,
Is it allowed to weld 40 mm root gap with backing plate as per AWS D1.1, please help me.
Regards,Arun Padman ManayilP Save a tree. Please don't print this e-mail unless you really need to