Re: [MW:29462] Pressure Relief Valve in Hydrotest

Relief valve is preferable in any pr vessel hydrotest. It is not mandatory. But if you exceed the hydrotest pr, designer has to recalculate and confirm that the pr is acceptable. Or else the vessel is liable for rejection . 
Rgds
Prakash Gotimukul
AIS, Authorised Inspection Associates LLC Texas
Consultant ASME/ISO/PED/IBR
Mob:+971 55 711 4761


Virus-free. www.avg.com

On Wed, Apr 3, 2019 at 10:17 PM 'Mac Palola' via Materials & Welding <materials-welding@googlegroups.com> wrote:
Dear Sirs,


Do we have any basis on ASME that PRV in test manifold is required during hydrotest?


Thank you.


Best Regards,

Mac Palola

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone