UG-99
CAUTION: A small liquid relief valve set to 11/3 times the test
pressure is recommended for the pressure test system, in case
a vessel, while under test, is likely to be warmed up materially
with personnel absent.
(i) Vents shall be provided at all high points of the vessel
in the position in which it is to be tested to purge possible
air pockets while the vessel is filling.
On Thursday, April 4, 2019 10:17 AM, 'Mac Palola' via Materials & Welding <materials-welding@googlegroups.com> wrote:
Dear Sirs,
-- Do we have any basis on ASME that PRV in test manifold is required during hydrotest?
Thank you.
Best Regards,
Mac Palola
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.
No comments: