HA
Dear all
We have aluminum 5083 tank which have some small hopes in shell plates
We prefer to go for injection wields to close these hopes
Holes are in 5 mmm diameter
Can you advice procedures and electrode to be used?
Regards
HA
On Mar 18, 2017 6:05 PM, "Hani Al Masry" <hanyonalfy@gmail.com> wrote:
ThanksFor steel plates you can consider it as X52For now just to explain for client when we weld the steel plates X52 to the pipes X65 We can use the WPS/PQR prepared for X65 and so onThe pipes specifications are API 5L Gr. X60 PSL2, NACE PIPE or EquivalentOn Sat, Mar 18, 2017 at 8:41 AM, Krishnnaa26 <krishna.bhpvteam@gmail.com> wrote:HiDesign/fabrication code/specifications are not specified. I think Client specifications will apply for this joint.X65 grade is P1 Gr 2 as per ASME Sec IXS355 is a structural grade steel and not defined under ASME Sec IX.An equivalent grade P355 (pressure vessel plate) is also P1 Gr 2 as per ASME Sec IX.There is SMYS difference between X65 and S355. And S355 is approximately equivalent to X56.If API 1104 is considered, X65 WPS can be used down to X46 grade i.e., X56 grade is covered.But Client specifications shall take precedence, if any.I think the WPS is acceptable provided meeting the properties required for pull head joint.And I guess the weld would be cut-out re-weld with mating X-65 line pipe.Based on this, the Client can be approached for approval.But the WPS cannot be used for other applications as S355 is not defined in Sec IX.Krishnnaa26
On Saturday, 18 March 2017 10:51:48 UTC+8, hanyon wrote:Dear AllPlease advice we have to fabricate some pulling heads from pipes gradesX60 and X65 with plates grade S355We proposed WPS for welding of X65 as the higher grade to be covered also for X60 and for S355Is these WPS 's are enough?or we need other?HARegards
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAKOkEzeZx1czv7fbS908cxZ47KQydUAWmH4KJbi_RZrn8OpZ7g%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.