Tuesday, January 31, 2017

[MW:26009] Re: ASME IX - Welder's qualification Thickness range

Hi

Procedure qualification / Welder qualification


What is the different between Thickness Sec IX , API1104 & D1.1



On Wednesday, March 9, 2011 at 8:13:49 PM UTC+3, Tunisian Quality Engineer wrote:
Hi all,

  As per ASME sect IX table QW-452-1(b), for welder's qualified in test coupon thickness greater or equal than 13 mm, he's will be qualified to wed thickness " Maximum to be welded"

May my interpretation is true ??
In this case, Can i  qualify all welder's in 13 mm thickness, he will be qualified for all thick ( PWHT is not essential variable for welders) and cover all thickness range ?

Regards

--
زكرياء غراب
GHRAB Zakaria
مسؤول عن الجودة
QA/QC SENAD
مشروع المحطة الحرارية ـ الوحدة الرابعة
المحمدية ـ المغرب

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/977c8bc6-0fbd-41b9-9bef-6203683a13b9%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...