Hello,
Defects can survive an hydrotest, then it can grow and appears as a leak, as César Vitero wrote some defects could grow during logistics or assembling.
Sergio Muñoz
IWE-IIW
http://Weld-ING.tk
El lunes, 2 de febrero de 2015, 22:10:12 (UTC-5), raouf salhi escribió:
-- Defects can survive an hydrotest, then it can grow and appears as a leak, as César Vitero wrote some defects could grow during logistics or assembling.
Sergio Muñoz
IWE-IIW
http://Weld-ING.tk
El lunes, 2 de febrero de 2015, 22:10:12 (UTC-5), raouf salhi escribió:
Dear experts;We have a skid of piping 10 " and 2 " API 5L welded and inspected according B 31.3.we made already the internal hydro test ( two houres at 375 bar) in workshop and the result was satisfactory , we repeat the same hydrotest in the client workshop and we found a leak in one 2 " joints.the RT report for this weld mention only undercut ( acceptable).how we can explain this ?regardsSALHI RaoufQA/QC Engineer
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/186a7a82-379f-485d-8512-e8f35c162387%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.
No comments: