Saturday, February 21, 2015

[MW:22909] Re: Excess penetration measurment in Radiograph

Dear Sundar ,

I believe all have given their input and the good one is to do UT or you can go for gauge pigging which could help u to understand if it is excess or not.

Regards
Pratish 

On Wednesday, February 18, 2015 at 1:49:32 AM UTC+5:30, sundarrajan kumaraswamy wrote:
  How to measure the excess penetration from the Radiograph of Small bore piping  DWDI superimpose Radiograph shows low density near the inner wall,
what is acceptance criteria for excess penetration as per ASME B 31.3 code, Please clarify the IMAGE CONTRAST GRAPH method .

Regards,

K.Sundar Rajan

--
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/aaa05311-73f1-44c9-8462-7d967518a773%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:34919] Welder qualification certificate

Dear All     anyone can share a format for welder certificate and card format        Thanks & Best Regards Saleem manhappulath Mob:+9665...