you have got the answer, it is exempted from impact
-- On 13 February 2015 at 04:49, Mohit Aggarwal <aggarwalmohit05@gmail.com> wrote:
Dear Sir,
In 2.5 mm thk of base metal if you take, is it possible to do impact testing after final machining.As per Ug-84, Impact specimen can't be make from 2.5 mm thk!Best Regards,
Mohit Aggarwal.On 10-Feb-2015 9:17 am, "Raghuram Bathula" <raghurambathula@gmail.com> wrote:Q1: since full mechanical tests are not done on 5mm coupon, the combination will qualify from 5mm and not 2.5mm (QW451.1)--On 9 February 2015 at 21:38, 'Ahmed Husain' via Materials & Welding <materials-welding@googlegroups.com> wrote: