Monday, February 2, 2015

[MW:22791] leak in welded joint

Dear experts;

We have a skid of piping 10 " and 2 " API 5L welded and inspected according B 31.3.

we made already the internal hydro test (  two houres at 375 bar) in workshop and the result was satisfactory , we repeat the same hydrotest in the client workshop and we found a leak in one 2 " joints.

the RT report for this weld mention only undercut ( acceptable).

how we can explain this ?

regards

SALHI Raouf
QA/QC Engineer

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...