Dear All
-- In lamination check by straight probe , some lamination and inclusion detected but they have a echo height less that 15%. Acceptance of project is level B of ASTM A578.
Now I want to know in 8.2 of A578 , small discontinuities must have total loss of back reflection or not?
Grade of material is API 2H GR 50 Z.