Both belong to SFA 5.18 and has same F & A nos.
Er 70 S-2 has triple de-oxidizers like Al, Ti, Zn and helps to produce 100 % x-ray quality welds.
Er 70 S-6 is higher with percentage of Mn & Si comparatively, and forms MnO2, SiO2 but,
consistency in the quality of weld not assured.
So, choice is different and up to u to decide.
C. Sridhar.
From: S.Mohammed <mohd52100@gmail.com>
To: "materials-welding@googlegroups.com" <materials-welding@googlegroups.com>
Sent: Sunday, 1 June 2014 12:00 PM
Subject: [MW:20945] C-Mn WPS.ER 70S2 to ER 70S6.
Dear all
Have WPS GTAW.for C-Mn with ER 70S2. %100%Ar.
Can i used ER70S6 instead of ER70S2.?
Or need qualification? Due to high Mn %.
Regards
Mohd.
-- Mohd.
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.