On 18 June 2013 22:49, ABHISHEK SINGH <mech.abhi17@gmail.com> wrote:
We are doing welding of IS2062 with IS276 GR1(Austenitic Mangnese steel)..During Transverse tensile material failed in HAZ area and we are getting 319 MPa UTS but we need about 500 MPa.Plz suggest...
Abhishek Singh
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.