Tuesday, June 18, 2013

Re: [MW:17955] Measurement of interpass temperature

There are 2 locations you need to consider,
 
1. For maximum temperature, you need to measure it on the Weld Bead
2. For minimum temperature (minimum preheat to be maintained) you need to measure it 75mm from the weld toe on either side. 
 
Thanks & Regards

J.Gerald Jayakumar
00968-99438165
From: sevak hiren <hirensevak80@gmail.com>
To: materials-welding@googlegroups.com
Sent: Monday, June 17, 2013 3:54 PM
Subject: [MW:17950] Measurement of interpass temperature

Dear Experts,
 
Can anybody explain at which location interpass temperature to be measured during welding ?
 
Also what diference it will make in the weld metal property if we follow the wrong location of measurement of interpass temperature ? 
 
Is it written in any where in any code, where interpass temperature to be measured ?
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
 
 


No comments:

[MW:34920] Tubesheet Hole step

Hello Team, I have one question any tolerance given for tubesheet Hole step. Please do needful. Regards, AP  -- https://materials-...