Re: [MW:15423] electrode change without requalification

yes. you can!
E7018-1 is better than E7018 in Low temperature Impact Value.
 
 
Roy
 
Sent: Friday, September 28, 2012 3:41 PM
Subject: [MW:15415] electrode change without requalification
 
Dear friends,
 
is it possible to change an E7018-1 electrode to E7018 in a WPS without requalification.
Charpy V notch test value is applicable in this case.
Code is AWSD1.1.
I found in table 4.6 in AWSD1.1 as changing of  electrode  is possible with the same SFA number and F number and A number.
Please advice..........
--
Thank you,
 
Sandeep.k.p
Dubai,UAE