"QW-203 Limits of Qualified Positions for Procedures
Unless specifically required otherwise by the welding variables (QW-250, a qualification in any position qualifies the procedure for all positions. The welding process and electrodes must be suitable for use in the postions permitted by the WPS. A welder or welding operator making and passing the WPS qualification test is qualified for the psotion tested. See QW-301.2."
Therefore in general, without impacts qualification in any position will qualify all postions. However, you should verify that the process does not have special limitations on position(s) - you do this by looking at the tables QW-252 thru QW-265 as appropriate and also by reviewing the requirements for special processes per QW-283 through QW-290 if applicable.
John Henning
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Vikas Bhandari
Sent: Sunday, February 07, 2010 7:27 AM
To: materials-welding@googlegroups.com
Subject: [MW:4246] WPS without Impact Test
Hi
AS per SEC IX, If one WPS is qualified in 3G position for what other positions it is qualified (please give the reference clause).
Thanks
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.