Skip to main content

[MW:4340] RE: 4339] Fwd: Querry regarding the PWHT

If you are a contractor you don't have this choice, if are a designer you need demonstrate to the owner not only with a qualified WPS, but a comparable service experience and other factors as indicated in the para 331.2.2.
 
Note: you need to qualify your own welding procedures, classified documents such as WPS/PQR can't be shared in a public domain. However members may share similar service experience if any body come across, which may be useful to you.
 


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Sudheer Babu
Sent: Thursday, February 18, 2010 11:33 AM
To: materials-welding@googlegroups.com
Cc: Sameer Wakde
Subject: [MW:4339] Fwd: Querry regarding the PWHT


Dear Sir

Good morning. I want your help in the following matter

We are doing the CWS/CWR line having dia from 80" ~ 112" & thickness over 20 mm upto 28.58 mm O.P 5.5 Kg/Cm2.

We are carrying PWHT due to the thickness requirement, but we want to deviate as the para 331.2.2 of B31.3. So if anybody have qualified WPS without PWHT in such cases, please guide me & send the WPS for the reference purpose.

With warm regards

--
Sameer Wakde
DFCU & AU PROJECT
SAMSUNG Engineering
Bharuch, India
+91 9714349279

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...