Friday, February 26, 2010

Re: [MW:4383] Failure of PQR in All Weld Tensile

Hi,
make sure the current, voltage and travel speed is within the limit of manufacturer recommendation.
When making all weld tensile specimen there should be uniform finish on the specimen.
 
regards,
Ibrahim


 
On 26 February 2010 07:09, prashant pansare <prashantpan_99@yahoo.co.in> wrote:
Dear All,
We are working on PQR & deatails are as folows :
Appl. Code - DNV OS F101,2000
PQR - Through THickness Repair. (SMAW)
Base Metal - API 5L X GRADE 60 - 12.75" OD X 14.3 mm THK.
Filler Metal - E-7018 H4R
Position -6G
After mechanical tests, we are getting all values in acceptable limits except All Weld Tensile results.(Reqd- 517 Mpa & Actual - 483 / 493 Mpa)
What is the reason & solution for the same?
Pl. reply.
PSP  


Your Mail works best with the New Yahoo Optimized IE8. Get it NOW!.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--
Thanks & Regards
Muhammed Ibrahim PK

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone