Wednesday, April 15, 2009

[MW:1963] SS 410 overlay with E 309L MO barrier layer

Dear all

I have problem in the overlay of SS 410 on SA 516 Gr 70 with FCAW
process

- I am unable to achieve the carbon % 0.06
- failure in bend test
- unable to achieve Ni content of 0.6%

As required the barrier layer of E309Lmo which contains high value of
Ni and Cr .

Please let me know is it possible to achieve 0.6% Ni in clad layer
with height of 6mm only.

how to clear the bend test ? or waiver from client is the only option.

Looking for you valuable suggestions.

JASPAL SINGH

919996624244

--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

[MW:34920] Tubesheet Hole step

Hello Team, I have one question any tolerance given for tubesheet Hole step. Please do needful. Regards, AP  -- https://materials-...