Monday, April 27, 2009

[MW:2044] Re: EN 287-1 welder qualification

Hello
 
If the welder is qualified in 6G than he can automaticaly qualified in 2G,3G,4G so you can use him in tank job.
 
Regards
 
B.K.Shah 

On Sat, Apr 25, 2009 at 3:19 PM, daniel iordache <daniel.iordache@gmail.com> wrote:

Hello,

i have the following situation.......

i have to test some welder coming from other sites acc. with EN 287-1........

the question is .....my project is tank erection and facilities .....

if the welder will pass 4" pipe butt weld 6G( h-l045)  they will cover
also plates and fillet welds..

thanks

Daniel
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...