Wednesday, April 15, 2009

[MW:1961] Re: PWHT

True or False is not the point to be worried

As per the section stated by you it is acceptable.

regards

JASPAL SINGH

919996624244

On Apr 14, 1:08 pm, "Torkaman" <Torka...@sadidjs.com> wrote:
> Dear All.
>
> Acc. to ASME B31.1 for material's with P No.1 & THK>19 mm, PWHT is required.
> But when min. preheat 95oC is applied, PWHT is non mandatory. Is it true?
>
> Best regards,
>
> Mehrdad

--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...