Skip to main content

[MW:2000] Re: effect of H on notch strength

Chaps,
 
Please find the attachment, hopefully clarify the things,
 


 
On Tue, Apr 21, 2009 at 7:36 PM, Ali Asghari <asghariali@rocketmail.com> wrote:
hi oven
thank you for answer,but i dont understand yet.
because the toughness in -100 is more than in 50,why?
another question:this figure is true in all steel?
regard advance


From: Owen Jenkins <owen@osjl.co.uk> Sent: Sunday, April 19, 2009 12:20:17 PM
Subject: [MW:1985] Re: effect of H on notch strength

Ali,
The top line shows the toughness of the base material without hydrogen embrittlement occurring - toughness increases steadily with increasing temperature.
 
The lower, V-shaped line shows that the effect of hydrogen embrittlement is worst at about 50°C, decreasing rapidly as the temperature increases (and the ability of the hydrogen to diffuse out of the metal increases) and also decreasing at lower temperatures, where reaction rates are much lower and the density of hydrogen increases, hence its volume decreases.
 
Other may wish to add more to this simple approach. Does this help?
 
Regards,
Owen.
----- Original Message -----
Sent: Saturday, April 18, 2009 11:31 AM
Subject: [MW:1980] effect of H on notch strength



hi
can anybody explain about this picture?
rgds.











--
Thanks & regards,

K.Babu
Welding Engineer,
PPL Shipyard Pte Ltd
Singapore
HP:  +65 94815990
Skype: psgbabu


--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...