Wednesday, April 15, 2009

[MW:1957] RE: 1954] Flux to SAW wire proportion

 If you use Flux recovery system , For CS , It is in the ratio about 1Kg Wire    with 0.8 Kg Flux  and you can reuse the flux once The3n you can still reduce to about 0.7 However it depends upon the quality of flux you use.

ii) LAS with Higher value of Impact , Reusing is not recommended We get ratio of 1:0.9

Regards

 

Hegde P.B.

09714714803

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Muhammed Ibrahim
Sent: Tuesday, April 14, 2009 11:26 PM
To: materials-welding@googlegroups.com
Subject: [MW:1954] Flux to SAW wire proportion

 


Gents,

 

I would like to get an information regarding flux to SAW wire proportion ( for 1 Kg of Wire How much flux required?) . I expect suggestion from as many members whose are usining SAW.It will help to get a conclusion.

Thanks & Regards
Muhammed Ibrahim PK



--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone