[MW:2029] Re: WPS

Yes because P no. is 1 in both cases. and group no. is supplementry essential variable which will only become essential variable in case of impact test requirement.

On Wed, Apr 22, 2009 at 5:44 PM, parviz farhadi <parvizfarhadi@gmail.com> wrote:
Dear All,
 
Is it possible to use WPS of ASTM A106 Grade B and its PQR for ASTM A333 Gr 6?
 
Regards,
Parviz




--~--~---------~--~----~------------~-------~--~----~