As per QW 256, GTAW process,
QW 408 Gas, There is no essential variable for gas Backing for P.No.
-8. Austentic Stainless Steel. A312 & others.
So we can qualify WPS without gas backing/Bsckpurging.
Am i right or not?
Pl clear me
Regards
Srinivas
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.